[glow=red][/glow] Case Study hp8530p Dead
19 volt ok but 3.3 and 5volt not persent on coil from tps51120 but ic volt out check 51120 getting then again check found io faulty change io kbc1091nu case done....
Case Study HP8530P Problem Dead
-
- Newbie
- Posts: 10
- Joined: Tue Feb 23, 2016 12:47 pm
Re: Case Study HP8530P Problem Dead
Maximum 3v incase shot.
First we check io its may be short
Nice job
[ Post made via Android ]
First we check io its may be short
Nice job
[ Post made via Android ]

-
- Member
- Posts: 26
- Joined: Tue May 10, 2016 1:43 am
Re: Case Study HP8530P Problem Dead
goooooooood work its acommon problem in those models
- pradipwasewal
- Newbie
- Posts: 0
- Joined: Sat Jul 09, 2016 11:12 am
Re: Case Study HP8530P Problem Dead
well done sir
Re: Case Study HP8530P Problem Dead
nice
[ Post made via Android ]
[ Post made via Android ]

-
- Member
- Posts: 17
- Joined: Thu Jun 16, 2016 7:55 am
-
- Guru
- Posts: 512
- Joined: Fri Aug 26, 2016 11:43 am
- Location: SHUBHAM ENTERPRISES MOTIHARI
Re: Case Study HP8530P Problem Dead
thanks for sharing
Who is online